Grounding drums and IBCs (Intermediate Bulk Containers).

Grounding drums and IBCs (Intermediate Bulk Containers).

Filling or emptying a metal drum with a flammable liquid generates electrostatic charges that build up on the container. If the drum is not earthed, a single spark towards the filling lance or the operator is enough to ignite the vapours. Logic ECS-RF systems provide a long-lasting earth connection with a resistance below 10 Ω, as recommended by technical specification IEC TS 60079-32-1, combined with two dedicated earthing clamps: the CLPM, designed to pierce through the paint layer on drums thanks to its carbonitrided steel teeth, and the IS1L, with built-in LEDs that show the operator the status of the connection. These solutions are designed and manufactured in Italy by Logic for transfer, packaging and filling areas and weighing rooms in the chemical, pharmaceutical and cosmetics industries.

Why drums and IBCs are a critical point

Drums, totes and IBCs are moved around constantly: every transfer means a new connection to make, often by different operators and with different containers. It is precisely this repetition that makes the risk real.

The risk increases when:

  • the drum is painted: paint is an insulator, and a clamp without suitable teeth rests on the surface without making contact with the metal container
  • the container stands on pallets or non-conductive floors, often dirty, which insulate it from earth
  • solvents and low-conductivity liquids are being transferred, which retain the charge for longer
  • the liquid is often transferred by free fall, which increases charge generation

This is why earthing must be carried out before every transfer, on every container.

The paint problem: why the clamp makes the difference

Many static electricity incidents do not happen because there was no clamp, but because the clamp was attached and was not making contact. On a painted drum, a generic clamp can sit on the paint and give the operator a false sense of security.

The CLPM clamp has been designed specifically for drums:

  • high clamping force, to keep contact even if the drum is moved
  • shaped, carbonitrided contact teeth that pierce the surface layer of paint and reach the metal
  • compact size, for quick and easy everyday use

Alternatively, the IS1L clamp is available, with built-in LEDs that tell the operator at all times whether the earth connection is actually made.

How ECS-RF monitoring works

The clamps are connected to a monitoring unit from the ECS-RF range, which verifies the connection to earth and checks that it stays below the 10 Ω threshold over time.

The monitoring electronics have SIL2 safety integrity level according to IEC 61508 and check the connection continuously throughout the transfer. If the resistance to earth exceeds the safety threshold, the system stops the process and alerts the operator. The range includes versions that can be installed in ATEX Zone 1/21, in ATEX Zone 2/22 or on a DIN rail in an electrical panel in a safe area.

Main technical specifications

Feature

Details

Resistance threshold

< 10 Ω, continuous monitoring as per IEC TS 60079-32-1

CLPM clamp

For drums, high clamping force, teeth that pierce the paint

IS1L clamp

Built-in status LEDs

Safety integrity level

SIL2, according to IEC 61508

Monitoring unit installation

Available for:

  • ATEX Zone 1/21
  • ATEX Zone 2/22
  • Safe area, DIN rail in electrical panel

Power supply

230 Vac or 24 Vdc, to be specified when ordering

Temperature range

Unit in safe area: -20 °C ≤ Tamb ≤ +70 °C

Unit in ATEX Zone 1/21: -20 °C ≤ Tamb ≤ +40 °C

Certifications

  • ATEX: 2014/34/EU [BVI 17 ATEX 0007 X]
  • Safety Integrity Level: SIL2 – IEC 61508

Available accessories

  • CAB-ECS-6C1.0: extension cable from the electronics inside the panel to the local junction box, suitable for intrinsically safe “Ex i” circuits
  • SP5 / SP10: 5 or 10 metre coiled cables, for a more flexible clamp connection
  • CR20: cable reel with a cable extending up to 20 metres, useful when containers change position in the area
  • ECS-MULTI: electrical panel for installing several monitoring systems in a multipoint

Why choose Logic

In a weighing room, a transfer area or a filling area, drum earthing is repeated dozens of times a day. Logic designs these areas as complete plants, not just as a device supplier, and has therefore developed clamps built for repeated use: a compact clamp that pierces paint, for those working with painted drums, and a clamp with LEDs, for those who want the connection status visible at a glance.

Frequently asked questions (FAQ)

  • Why does a metal drum need to be earthed if it is already standing on the floor?
    Because pallets, resin floors, plastic bases and dirt can insulate the drum from earth. Contact with the floor does not guarantee an adequate path for the charges to dissipate.
  • Will any clamp do for a painted drum?
    No. Paint is an insulator: if the teeth do not pierce it, the clamp rests on the surface layer without connecting to the metal. The CLPM clamp has teeth designed to go through the paint layer.
  • Why does a metal drum need to be earthed if it is already standing on the floor?
    With the IS1L clamp, the operator sees it directly from the LEDs on the clamp. When CLPM clamps are used, the ECS-RF monitoring system verifies the connection electronically against the 10 Ω threshold required by technical specification IEC TS 60079-32-1, and shows the status on the local junction box.
  • Should earthing be done before or during the transfer?
    Both before and during. Charge is generated from the moment the liquid starts to flow, so the connection must already be active before the transfer begins and maintained throughout the operation.