INSTRUMENTS

DTR-NET

DIGITAL INTERFACE
FOR LOAD CELLS 

The DTRNET series instruments are microprocessor interface units for strain gauge load cells. A simple installation and immediate use make these products suitable for the specific requirements of industrial plants. Available with interfaces Fieldbus Profibus-DP® o Profinet®.

GENERAL CHARACTERISTICS

  • Durable metal Housing and Din rail mounting
  • Communication bus Profinet® o Profibus-DP®
  • Compatible with remote display Logic DLC3-RD o BEKA® (ATEX Zona 1)
  • Meets the EMC provisions of Directive 2004/108/CE and has been tested according to the harmonized standard EN 61000-4 ed EN 61000-6

Galvanic isolation through DC / DC converter between 24Vdc power supply, load cell, fieldbus and remote display for maximum noise attenuation. The instrument is electrically calibrated at the factory.

PROFIBUS-DP® slave interface (up to 12 Mbit / s): allows easy connection to PLC / PC up to 124 units on a single link.

PROFINET® slave interface (10/100 Mbit / s) with integrated Ethernet switch for cascade connection.

 

TECHNICAL FEATURES

Load cell power supply

5 Vdc

Maximum current

:150 mA (4 cells from Ri=350Ω)

Maximum sensitivity

40 nV/div

Input signal

da -4mV/V a +4mV/V

Maximum resolution

19 bit + segno (524.288 divisions a 4mV/V)

Conversion speed

10 o 80 sample/s (settable)

Supply voltage

24Vdc + 10%, 3 W max

Dimensions

 144 x 72 x 120 mm (L x H x D)

DTRNET-PN

Interface for load cells with communication port Profinet®

Mounting from inside panel on DIN rail

  • Factory calibration in the 0÷4 mV/V range
  • Diagnostic led fo power status and active communication
  • Threshold of stable weight via Fieldbus
  • Digital filter can be set via DIP switches with 4, 8, 16, 32 readings
  • Serial output for remote indicator with protocol support BEKA®
  • PROFINET® slave interface (10/100 Mbit/s) with integrated Ethernet switch for cascade connection.

DTRNET-PB

Interface for load cells with communication port Profibus-DP®

Mounting from inside panel on DIN rail

  • Factory calibration in the 0÷4 mV/V range
  • Diagnostic led for power status and active communication
  • Stable weight threshold that can be set via Fieldbus
  • Digital filter can be set via DIP switches with 4, 8, 16, 32 readings
  • Profibus-DP® address. that can be set via DIP switch
  • Serial output for remote indicator with BEKA® protocol support
  • Profibus-DP® slave interface (up to 12Mbit/s): allow easy connection to PLC/PC up to 124 unison a single link.